Protection System - 02 (Part 2) Voltage Transformer (By CoEE)

Technical sharing on Electrical Protection System: Voltage Transformer by Crux of Electrical Engineering, Malaysia.
Presentation dan komentar dalam Bahasa Malaysia (Malay Language)
Yotube link: https://youtu.be/TkF6PdxU9ss

This video is on 02 part 2 Voltage Transformer, which is one the following covered topics:
01 Introduction ============ 02 CT and VT - Part 2 - On VT ============ 03 Relay Classification 04 Grandfather of all Protection – OCEF 05 Directional OC

Tuesday, April 28, 2020

Protection System - 02 Current Transformer (By CoEE)

Technical sharing on Electrical Protection System: Current Transformer by Crux of Electrical Engineering, Malaysia. Presentation dan komentar dalam Bahasa Malaysia (Malay Language) Youtube Video Link: https://youtu.be/MaygKuZnUpk

This video is on 02 Current Transformer, which is one the following covered topics:
01 Introduction ============ 02 CT and VT -> Only CT in this video ============ 03 Relay Classification 04 Grandfather of all Protection – OCEF 05 Directional OC 06 Differential Protection

Sunday, April 26, 2020

Protection System - 01 Introduction (By CoEE)

Technical sharing on Electrical Protection System by Crux of Electrical Engineering, Malaysia. Presentation dan komentar dalam Bahasa Malaysia (Malay Language)

Youtube link: https://www.youtube.com/watch?v=3C0kHLO1_2A


This video is on 01 Introduction, which is one the following covered topics: ============ 01 Introduction ============ 02 CT and VT 03 Relay Classification 04 Grandfather of all Protection – OCEF 05 Directional OC 06 Differential Protection

Synchronizing Check Relay atau Geganti Pasti Segerakan (ANSI 25)

=================
Synchro Check Relay (ANSI No. 25)
=================
Mesti tuan-tuan selalu jumpa relay ni kan? Kebanyakan multi function relay microprocessor/numeric sudah ada built-in dalam relay, masih ada juga yang jenis single function relay khas untuk synchro sahaja. Selalu digunakan untuk memberi permissive untuk CLOSE Breaker antara 2 punca berlainan.

Apa syarat-syarat untuk kita boleh synchro?
1. Voltan mesti lah sama
2. Phase angle mesti lah sama
3. Phase rotation mestilah pada arah yg sama
4. Frequency juga mesti lah sama

Tapi tuan-tuan tengok dalam protection relay, setting untuk function 25 ada beberapa typical setting yg ada. Ini adalah contoh untuk Siemens Reyrolle 7SR2244. Seperti pada gambar.


=======
7SR2244
=======

Voltage reference: Vab.
Ini bermakna reference digunakan adalah Voltage red (a) dan yellow (b) phase. Relay jenis ini mempunyai 2 voltage input (1 untuk incomer side - 4 wire (R, Y, B, N dan 1 lagi untuk bus bar - 2 wire sahaja). Jadi bila dipilih setting Vab, belah incomer automatic akan gunakan V_incomer (R-Y). Untuk voltage input 2, memandangkan hanya ada 2 wire sahaja, sambungan dari VT atau PT belah bus bar side harus lah juga menggunakan V_bus (R-Y). Jika tidak memang tidak akan synchro la sampai ke sudah.

Monday, April 20, 2020

ABB REF615 DEMO (Link to ABB)




ABB REF615 DEMO: http://protectionrelays-simulator.abb.com/…/simulator_demo.…

Assalamualaikum dan salam sejahtera semua,

Ni ada satu link bagus untuk interaksi dengan relay ABB jenis REF 615 untuk Feeder.

Antara interaksi yang boleh boleh dilakukan:-

1. Fault simulation (OC, EF, Dir EF)

Friday, April 17, 2020

How To Check IDMT Trip Time (Spot Check) During Relay Testing



Technical sharing on How To Check IDMT Relay Calibration by Crux of Electrical Engineering, Malaysia. 


Material in English tapi presentation dan komentar dalam Bahasa Malaysia (Malay Language) 

The topics are on: 
1. Explanation on typical OCEF Relay Calibration report 
2. Introduction to IDMT

Monday, April 13, 2020

Technical Sharing: Fuse by CoEE




Technical sharing on fuse by Crux of Electrical Engineering, Malaysia.

Material is in English tapi presentation dan komentar dalam Bahasa Malaysia (Malay Language)

Material link: https://bit.ly/2yNOnar. It's free, but please give some credit in your website, presentation, video or pictures to www.cruxofee.com if you plan to use it.

The topics are on: 
  • Definitions in a fuse rating name plate
  • Fuse Characteristic
  • Type of Fuses
  • Fuse Construction
  • Selection of Fuse for Motor, Transformer and Capacitor
  • Fuse and Overload/IDMT discrimination i.e. discriminate between fuse and overload/ IDMT OC to protect the contactor / vacuum contactor unit

=======================
Crux of Electrical Engineering
========================
Email: cruxofee@gmail.com 
 

AD

Disclaimer

The views expressed at, or through this site are those of individual authors writing in their individual capacities and professional experiences only. All liability with respect to actions taken or not taken based on the contents of this site are hereby expressly disclaimed. The content on this posting is provided "as-is", no representations are made that the content is error-free.

About Me

My photo
Kerteh, Terengganu, Malaysia
Electrical engineering Services and Training, Electrical engineering fundamental, Professional journey of an electrical engineer in Malaysia, Electrical technical sharing and tutorial, Simple electrical programs and calculators; Electrical Design, Maintenance and Testing. Electrical engineering services, training and consultancy in industrial as well as oil & gas sector. CoEE website also serves as a platform for electrical technical sharing, and engineering professional advancement in Malaysia