RCCB / RCD - Hangpa ni kenai ke tak kenai rating dia?


RCCB ni Residual Current Circuit Breaker atau nama am RCD - Residual Current Device. Dalam BM ... kita panggil Peranti Arus Bocor Ke Bumi.

Dulu-dulu, la ni pun ada lagi, orang duk panggil ELCB atau Earth Leakage Circuit Breaker. Tapi jenis ELCB ni sebenarnya ni orang pakai dulu-dulu dan ia adalah jenis Voltage Operated. Lain dari RCD yang mana dia adalah jenis Residual Current Operated. Jika nak tahu lebih lanjut apa beza ELCB dan RCD ni boleh ke pautan ni https://www.youtube.com/watch?v=Wo7IUzUT-rU

Harap hangpa semua ni panggil la RCD ke RCCB (Residual Current Operated). Jangan tersilap pula dengan ELCB (Voltage Operated)

Tuesday, August 17, 2021

Earth Leakage Circuit Breaker, Residual Current Device, Earth Leakage Relay & Earth Fault Relay

 Title: ELCB - RCD - ELR - EFR

#################### Video Link: https://youtu.be/Wo7IUzUT-rU

Technical sharing on the following items: 1. ELCB - Earth Leakage Circuit Breaker 2. RCD - Residual Current Device 3. ELR - Earth Leakage Relay 4. EFR - Earth Fault Relay

Tuesday, June 29, 2021

Earth Fault Vs Earth Leakage (Arus Kerosakan Bumi Vs Arus Bocor Bumi)

 


Arus Kerosakan Bumi / Earth-fault current :
========
- Current flowing to earth due to an insulation fault.
- Arus yang bocor ke bumi apabila ada kegagalan penebat.

Arus Bocor Ke Bumi/ Earth-leakage current :
========
- Current flowing from the live parts to earth or extraneous conductive parts in the absence of an insulation fault.
- Arus bocor ke bumi yang mengalir dari bahagian-bahagian litar HIDUP atau dari bahagian pengalir elektrik (yang HIDUP) dengan ketiadaan kegagalan penebat.

What are their differences?
========
a. Earth fault protection is intended to protect equipment when an insulation fault occurs, for instance a direct contact between a live conductor and earth. In such a situation, great fault currents will flow back to the transformer through its neutral point when its connected to earth
b. This is not the case of earth leakage protection, where faulty currents are generally much lower and the protection is dedicated, for example, to avoid hazards to human beings or animal

Saturday, June 19, 2021

Journey to Jurutera Elektrik Kompeten (JEK) Malaysia, Sharing Session with University Malaysia Perlis (UniMaP) 2021

Video Play List Link: Journey to Jurutera Elektrik Kompeten (JEK) Malaysia 

Talk and sharing on Jurutera Elektrik Kompeten (JEK) with University Malaysia Perlis 3rd year electrical engineering student under their Professional Engineer course which consists:

1. Jurutera Elektrik Kompeten (JEK) Presentation 2. JEK Q & A


#PE #PEPC #ProfessionalEngineer #ProfessionalEngineerPracticingCertificate #Malaysian #EET442 #UniMAP #UniversitiMalaysiaPerlis #JEK #JEP #JuruteraElektrikKompeten #SuruhanjayaTenaga #EnergyCommission

Routes To Professional Engineer in Malaysia, Sharing Session with University Malaysia Perlis (UniMaP) 2021

Talk and sharing on Routes to Professional Engineer with University Malaysia Perlis 3rd year electrical engineering student under their Professional Engineer course which consists of 5 parts:

Video Play List on Youtube: Routes to Professional Engineer

01 Introduction 02 Board of Engineers Malaysia 03 Institution of Engineers Malaysia 04 Routes to Professional Engineer in Malaysia 05 Question and Answer #PE #PEPC #ProfessionalEngineer #ProfessionalEngineerPracticingCertificate #Malaysian #EET442 #UniMAP #UniversitiMalaysiaPerlis



Electrical Contactor - Pengenalan serta Spesifikasi / Introduction and Specification

Electrical Contactor - Pengenalan serta Spesifikasi

Video Link in Bahasa Malaysia (Malay): https://youtu.be/mLvUerQ-l0k

Video Link in
English: https://youtu.be/mhvNEcBEnqs

Perkongsian mengenai Contactor dalam Bahasa Malaysia 1. Apa itu Contactor? 2. Penerangan Rating Pada Contactor 3. Voltage Sag Immunity dan Kaitan dengan Contactor 4. Jenis-Jenis Utilization Category 5. Making and Breaking Capacity 6. Kriteria Pemilihan Contactor ### NOTA PERCUMA ### Link: https://shorturl.at/gpGR7 ### FREE NOTES ###

Cara - Cara Protection System Mengesan Earth Fault / Earth Fault Detection Methods

 ### VIDEO ###

BAHASA MELAYU Link: https://youtu.be/92r1asm2bEc
ENGLISH Link: https://youtu.be/moV_wr9y5Tk

### VIDEO ### Perkongsian mengenai cara-cara Earth Fault dikesan dalam Protection System: 1. Residual Connection Current Transformers 2. Standby Earth Fault - Neutral to Earthing CT Connection 3. Core Balance CT or Zero Sequence CT 4. Metal Clad Frame Leakage Connection 5. Restricted Earth Fault Connection (REF) 6. Ground Fault or Neutral Displacement Over Voltage (59N)
### NOTA FREE/ FREE NOTES ### Link: https://shorturl.at/AFQ89 CORRECTION IN THE NOTES: For the last type of protection on 59N, there is a formula "Rp = Rs x N2". Whereby the 2 is supposed to be to the power of 2 or squared. ### NOTA FREE ###
 

AD

Disclaimer

The views expressed at, or through this site are those of individual authors writing in their individual capacities and professional experiences only. All liability with respect to actions taken or not taken based on the contents of this site are hereby expressly disclaimed. The content on this posting is provided "as-is", no representations are made that the content is error-free.

About Me

My photo
Kerteh, Terengganu, Malaysia
Electrical engineering Services and Training, Electrical engineering fundamental, Professional journey of an electrical engineer in Malaysia, Electrical technical sharing and tutorial, Simple electrical programs and calculators; Electrical Design, Maintenance and Testing. Electrical engineering services, training and consultancy in industrial as well as oil & gas sector. CoEE website also serves as a platform for electrical technical sharing, and engineering professional advancement in Malaysia